FewerJobs.
All jobs

Senior Facilities Mechanical Engineer (Wet Systems)

Micron Technology, Inc. - Penang, Malaysia - Grande

Posted Oct 19, 2026

Benefits

Parental leave
Not verified
Non-birth-parent leave
Not verified
Family-building benefits
  • Fertility benefits: Not verified
  • Adoption assistance: Not verified
  • Surrogacy assistance: Not verified
Mental health support
Not verified
Relocation assistance
Not verified
Childcare support
Not verified
Learning budget
Not verified
Verification
Not verified checked Nov 20, 2026
Salary
Not verified
401(k) match
Reported from DOL Form 5500 industry filing (not employer-specific)

Was this benefit information wrong? Tell us.

Role

Seniority
Senior From the posting source checked Nov 18, 2026

Schedule

Shift type
Not verified
Weekend work
Not verified

Company

Equity
Offered Verified - SEC 10-K source checked Nov 18, 2026

Application

Cover letter
Not verified
Assessment
Not verified
Deadline
Not stated

Where they hire

State eligibility is not yet verified.

About this role

Senior Facilities Mechanical Engineer (Wet Systems) Penang, Malaysia - Grande Our vision is to transform how the world uses information to enrich life for all . Micron Technology is a world leader in innovating memory and storage solutions that accelerate the transformation of information into intelligence, inspiring the world to learn, communicate and advance faster than ever. Systems Ownership Scope As the designated System Owner, the engineer holds end-to-end technical accountability for the following mechanical utility systems across their full lifecycle - build, construction, commissioning, and operation: Chilled Water - Medium-Temperature (MTCHW): centrifugal / screw chillers, primary-secondary or variable-primary pumping, cooling towers, and distribution to HVAC and process loads. Chilled Water - Low-Temperature (LTCHW): low-temperature chiller plant serving process and dehumidification loads with tighter temperature control. Process Cooling Water (PCW): closed-loop tool-cooling system - vertical/inline pumps, plate heat exchangers, filtration, chemical dosing, and detailed temperature/flow regulation according to tool specifications. Ethylene Glycol (EG) / Low-Temperature Loop: sub-zero glycol refrigeration package(s), pumps, filtration, and distribution for process temperature control. Associated cooling towers, water-treatment / chemical-dosing systems, expansion tanks, instrumentation, and BMS integration. Shows readiness and capability to incorporate AI-powered tools into everyday engineering tasks. These include predictive maintenance, energy management, and data-driven optimization of mechanical utility systems. This supports Micron's AI transformation and smart manufacturing objectives. Construction Phase - Build, Delivery & Commissioning Review the basis for the build, cooling-load calculations, and hydraulic sizing for chilled water, PCW, and EG systems against Micron global standards and applicable codes. Define chiller plant

Read the full description at micron.wd1.myworkdayjobs.com. FewerJobs shows a preview and links to the original posting.

Apply at micron.wd1.myworkdayjobs.com

Apply link verified; last checked Nov 20, 2026.

What verified means

Verified means a displayed claim has field-level provenance to a source FewerJobs pulled: a government or employer source, or the original job posting. Posting-sourced facts are employer-stated and are labeled separately from government records.

Related jobs